There is no single way to design a data center, and countless designs exist that cater to the unique needs of each business. But the following strategies can produce a data center design with superior efficiency and sustainability:
+
Tidak ada cara tunggal untuk merancang sebuah data center, dan ada banyak sekali desain yang memenuhi kebutuhan unik setiap bisnis. Tetapi strategi berikut dapat menghasilkan desain data center dengan efisiensi dan keberlanjutan yang unggul:
  
* Measure power efficiency. Data center operators can't manage what they don't measure, so use metrics such as PUE to oversee the efficiency of the data center. PUE should be a continuous measurement taken at frequent intervals, year-round, as seasons and weather can affect power usage.
+
* Measure power efficiency. Operator pusat data tidak dapat mengelola apa yang tidak mereka ukur, jadi gunakan metrik seperti PUE untuk mengawasi efisiensi data center. PUE harus menjadi pengukuran berkelanjutan yang dilakukan pada interval yang sering, sepanjang tahun, karena musim dan cuaca dapat memengaruhi penggunaan daya.
* Revisit airflow. Cooling is essential to safe operation of IT infrastructure, but airflow must be managed and optimized. This can include limiting hot air/cold air mixing, using hot aisle/cold aisle containment schemes and even using blanking plates to cover unused rack openings, which prevents cooled air from flowing to places that don't cool any gear.
+
* Revisit airflow. Pendinginan sangat penting untuk pengoperasian infrastruktur TI yang aman, tetapi aliran udara harus dikelola dan dioptimalkan. Ini dapat mencakup pembatasan pencampuran udara panas/dingin, menggunakan skema penahanan lorong panas/dingin dan bahkan menggunakan pelat blanking untuk menutup bukaan rak yang tidak terpakai, yang mencegah udara dingin mengalir ke tempat yang tidak mendinginkan peralatan apa pun.
* Raise the temperature. The colder a server room is, the more power-hungry and expensive it is. Rather than keeping the server room colder, evaluate the effect of actually raising the temperature. For example, rather than running a cold aisle at 68 to 72 degrees Fahrenheit, consider running the cold aisle at 78 to 80 degrees Fahrenheit. Most IT gear can tolerate elevated temperatures in this way.
+
* Raise the temperature. Semakin dingin ruang server, semakin haus daya dan mahal. Daripada menjaga ruang server lebih dingin, evaluasi efek dari menaikkan suhu sebenarnya. Misalnya, daripada menjalankan lorong dingin pada suhu 68 hingga 72 derajat Fahrenheit, pertimbangkan menjalankan lorong dingin pada suhu 78 hingga 80 derajat Fahrenheit. Sebagian besar perlengkapan IT dapat mentolerir suhu tinggi dengan cara ini.
* Try alternative cooling. An HVAC system might be standard for data centers, but consider ways to reduce or eliminate dependence on conventional HVAC. For example, data centers in cooler climates might reduce HVAC use and introduce cooler outside air -- termed free cooling -- into the facility. Similarly, HVAC can be supplemented or replaced by water-cooled chillers -- i.e., economizers -- or other heat-exchange technologies that use far less energy.
+
* Try alternative cooling. Sistem HVAC mungkin standar untuk pusat data, tetapi pertimbangkan cara untuk mengurangi atau menghilangkan ketergantungan pada HVAC konvensional. Misalnya, data center di iklim yang lebih dingin dapat mengurangi penggunaan HVAC dan memasukkan udara luar yang lebih sejuk -- disebut pendinginan gratis -- ke dalam fasilitas. Demikian pula, HVAC dapat dilengkapi atau diganti dengan pendingin berpendingin air - yaitu, economizers - atau teknologi pertukaran panas lainnya yang menggunakan energi jauh lebih sedikit.
* Improve power distribution. Data center power efficiency is often lost due to inefficiency in power-handling and distribution devices, such as equipment transformers, PDUs and UPS gear. Use high-efficiency power distribution gear and minimize gear -- both of which result in fewer steps and opportunities for loss.
+
* Improve power distribution. Efisiensi daya data center sering kali hilang karena inefisiensi dalam penanganan daya dan perangkat distribusi, seperti transformator peralatan, PDU, dan perlengkapan UPS. Gunakan roda gigi distribusi daya berefisiensi tinggi dan minimalkan roda gigi -- keduanya menghasilkan langkah yang lebih sedikit dan peluang kehilangan.
  
 
==Tantangan desain data center==
 
==Tantangan desain data center==

Revision as of 19:51, 27 April 2023

Sumber: https://www.techtarget.com/searchdatacenter/How-to-design-and-build-a-data-center

Merancang data center yang efisien bukanlah hal yang mudah. Tinjau komponen fasilitas dan infrastruktur pusat data dan berbagai standar sebelum Anda mulai. Data center adalah pusat teknologi operasi perusahaan modern. Pusat data menyediakan infrastruktur TI penting yang diperlukan untuk memberikan sumber daya dan layanan kepada karyawan bisnis, mitra, dan pelanggan di seluruh dunia.

Bisnis kecil atau menengah seringkali dapat mengimplementasikan "data center" yang berguna dalam batas-batas lemari atau ruangan nyaman lainnya dengan sedikit modifikasi, jika ada. Namun, skala besar yang terlibat dalam komputasi perusahaan menuntut ruang khusus yang besar yang dirancang dengan hati-hati untuk mendukung kebutuhan ruang, daya, pendinginan, manajemen, keandalan, dan keamanan infrastruktur TI.

Akibatnya, fasilitas data center mewakili aset tunggal terbesar dan termahal yang akan dimiliki bisnis -- baik dalam hal investasi modal maupun biaya operasional berulang. Para pemimpin bisnis dan TI harus memperhatikan masalah yang terlibat dalam desain dan konstruksi data center untuk memastikan bahwa fasilitas yang dihasilkan memenuhi kebutuhan bisnis sepanjang siklus hidup fasilitas dan keadaan bisnis yang berubah.


Apa komponen utama data center?

Ada dua aspek utama untuk data center mana pun: fasilitas, dan infrastruktur TI yang berada di dalam fasilitas. Aspek-aspek ini hidup berdampingan dan bekerja sama, tetapi dapat didiskusikan secara terpisah.

Fasilitas. Fasilitas adalah bangunan fisik yang digunakan untuk data center. Dalam istilah paling sederhana, data center hanyalah ruang terbuka besar tempat infrastruktur akan digunakan. Meskipun hampir semua ruangan memiliki potensi untuk mengoperasikan sejumlah infrastruktur TI, fasilitas yang dirancang dengan baik mempertimbangkan berbagai faktor berikut:

  • Space. Harus ada ruang lantai yang cukup -- ukuran meter persegi -- untuk menampung semua infrastruktur TI yang ingin diterapkan bisnis saat ini dan di masa mendatang. Ruang harus terletak di situs yang dipertimbangkan dengan baik dengan pajak dan akses yang terjangkau. Ruang sering dibagi untuk mengakomodasi berbagai tujuan atau jenis penggunaan.
  • Power. Harus ada daya yang memadai -- dalam watt, seringkali sebanyak 100 megawatt -- untuk mengoperasikan semua infrastruktur TI. Listrik harus terjangkau, bersih -- artinya bebas dari fluktuasi atau gangguan -- dan dapat diandalkan. Daya terbarukan dan tambahan/tambahan harus disertakan.
  • Cooling. Sejumlah besar daya yang dikirimkan ke pusat data diubah menjadi komputasi -- yaitu, kerja -- dan banyak panas, yang harus dihilangkan dari infrastruktur TI menggunakan sistem HVAC konvensional, serta teknologi pendinginan nonkonvensional lainnya.
  • Security. Mempertimbangkan nilai pusat data dan kepentingan kritisnya bagi bisnis, pusat data harus menyertakan akses terkontrol menggunakan berbagai taktik, mulai dari akses badge karyawan hingga pengawasan video.
  • Management. Pusat data modern biasanya menggabungkan building management system (BMS) yang dirancang untuk membantu pemimpin TI dan bisnis mengawasi lingkungan pusat data secara real time, termasuk pengawasan suhu, kelembapan, tingkat daya dan pendinginan, serta pencatatan akses dan keamanan.

Infrastruktur. Infrastruktur mewakili rangkaian peralatan TI yang luas yang digunakan di dalam fasilitas. Ini adalah peralatan yang menjalankan aplikasi dan memberikan layanan kepada bisnis dan penggunanya. Infrastruktur TI tipikal mencakup komponen-komponen berikut:

  • Server. Komputer ini menghosting aplikasi perusahaan dan melakukan tugas komputasi.
  • Storage. Subsistem, seperti larik disk, digunakan untuk menyimpan dan melindungi aplikasi dan data bisnis.
  • Networking. Perlengkapan yang diperlukan untuk membuat jaringan bisnis meliputi sakelar, router, firewall, dan elemen keamanan siber lainnya.
  • Cable and rack. Berkilometer kabel menghubungkan perlengkapan TI, dan rak server fisik digunakan untuk mengatur server dan perlengkapan lainnya di dalam ruang fasilitas.
  • Backup power. Uninterruptible power supply (UPS), flywheel, dan sistem daya darurat lainnya sangat penting untuk memastikan perilaku infrastruktur yang teratur jika terjadi gangguan daya utama.
  • Management platform. Satu atau lebih data center infrastructure management (DCIM) diperlukan untuk mengawasi dan mengelola pelaporan infrastruktur TI tentang kesehatan sistem, ketersediaan, kapasitas, dan konfigurasi.

Ketika sebuah bisnis memutuskan untuk merancang dan membangun pusat data, fokus alaminya adalah pada desain dan konstruksi fasilitas tersebut. Namun para pemimpin TI juga harus mempertimbangkan infrastruktur yang akan masuk ke fasilitas untuk memvalidasi proyek.

Bagaimana merancang data center

Tidak ada standar yang diwajibkan untuk desain atau konstruksi data center; data center dimaksudkan agar sesuai dengan kebutuhan unik bisnis secara keseluruhan, bukan sebaliknya. Namun, tujuan utama dari standar apa pun adalah untuk membangun platform yang terbaik. Bermacam-macam standar data center saat ini ada, dan bisnis dapat menggabungkan satu atau lebih standar -- atau bagian dari standar -- ke dalam proyek data center. Standar membantu memastikan perhatian yang memadai diberikan pada faktor-faktor ini, antara lain:

  • desain konseptual;
  • tata letak dan perencanaan ruang;
  • persyaratan konstruksi bangunan;
  • masalah keamanan fisik;
  • bangunan internal (mekanik, listrik, pipa ledeng dan sistem kebakaran);
  • operasi dan workflow; Dan
  • maintenance.

Di bawah ini adalah beberapa standar desain dan infrastruktur pusat data utama:

  • Uptime Institute Tier Standard. Uptime Institute Tier Standard berfokus pada desain, konstruksi, dan commissioning data center, dan digunakan untuk menentukan ketahanan fasilitas terkait dengan empat tingkat redundansi/keandalan.
  • ANSI/TIA 942-B. Standar ini melibatkan perencanaan, desain, konstruksi dan komisioning perdagangan bangunan, serta proteksi kebakaran, TI, dan pemeliharaan. Ini juga menggunakan empat tingkat peringkat keandalan, yang diterapkan oleh para profesional bersertifikasi BICSI.
  • EN 50600 seri. Serangkaian standar ini berfokus pada kabel IT dan desain jaringan serta memiliki berbagai konsep redundansi dan keandalan infrastruktur yang secara longgar didasarkan pada Standar Tier Uptime Institute.
  • ASHRA. ASHRAE guideline -- yang tidak khusus untuk TI atau data center -- terkait dengan desain dan penerapan pemanas, ventilasi, penyejuk udara, pendingin, dan bidang terkait.
Whatis-uptime-data-center-tier-standards.png

Selain itu, ada banyak variasi peraturan dan standar operasional yang dapat diterapkan pada data center. Standar peraturan termasuk HIPAA, Sarbanes-Oxley Act, SAS 70 Tipe I atau II dan Gramm-Leach-Bliley Act. Standar operasional dapat mencakup ISO 9000 untuk kualitas, ISO 14000 untuk manajemen lingkungan, ISO 27001 untuk keamanan informasi, Standar Keamanan Data Industri Kartu Pembayaran untuk keamanan kartu pembayaran dan EN 50600-2-6 tentang manajemen dan informasi operasional.

Standar membantu memastikan desain, konstruksi, dan pengoperasian data center yang tepat. Selain itu, penerapan dan dokumentasi yang cermat atas penggunaan standar yang relevan dapat membantu bisnis memastikan kepatuhan yang memadai melalui ketahanan fasilitas, manajemen, dan persiapan kelanjutan bisnis yang tepat.

Ruang fisik dan organisasi data center

Pada intinya, fasilitas data center tidak lebih dari ruang terbuka yang besar -- sebuah gudang yang disiapkan dengan hati-hati yang dimaksudkan untuk menjadi tuan rumah dan mengoperasikan infrastruktur TI yang menuntut. Meskipun data center kelas perusahaan dapat menjadi pekerjaan yang besar dan kompleks, masalah utamanya adalah masalah ruang sederhana yang dinyatakan dalam meter persegi.

Mungkin masalah ruang yang paling signifikan dan membingungkan adalah ukuran data center yang tepat untuk bisnis. Data Center sangat mahal: terlalu kecil, dan data center mungkin tidak memenuhi kebutuhan bisnis saat ini atau di masa depan; terlalu besar, dan modal yang sangat besar dapat disia-siakan untuk menyediakan ruang yang tidak terpakai. Sangat penting untuk membangun fasilitas yang menawarkan kapasitas pertumbuhan namun pemanfaatan yang optimal. Ukuran data center terkadang dianggap sebagai seni tersendiri. Banyak faktor lain yang perlu dipertimbangkan dalam data center termasuk yang berikut:

  • Lighting. Sebagian besar pencahayaan data data redup atau mati tanpa kehadiran manusia.
  • Suhu. Tuntutan pendinginan dapat menjaga suhu tetap rendah, sehingga manusia mungkin membutuhkan pakaian pelindung.
  • Noise. Kipas pendingin di lusinan -- bahkan ratusan -- server dapat menghasilkan hiruk-pikuk yang membutuhkan perlindungan pendengaran.
  • Berat. Peralatan berat, dan lantai harus dirancang untuk menahan beban yang ekstrim. Pertimbangan berat khusus mungkin diperlukan untuk lantai yang ditinggikan yang digunakan untuk menangani aliran udara pendingin.

Di luar ruang fisik, desain data center harus menyertakan pertimbangan cermat terhadap lokasi dan tata letak peralatan -- yaitu, di mana infrastruktur TI ditempatkan di dalam fasilitas. Fitur paling umum dari setiap tata letak data center adalah rak server -- atau, singkatnya, rak. Rak adalah rangka logam kosong dengan opsi penspasian dan pemasangan standar yang dimaksudkan untuk menampung perlengkapan TI yang dipasang di rak standar, seperti server, subsistem penyimpanan, perlengkapan jaringan, pemasangan kabel, sistem daya tambahan seperti perangkat UPS, dan opsi I/O seperti keyboard dan monitor untuk akses administratif.

Rak juga memainkan peran penting dalam skema pendinginan data center. Rak roda gigi umumnya diatur untuk membuat lorong panas dan dingin yang dapat meningkatkan efisiensi pendinginan dengan memungkinkan masuknya udara dingin ke lorong dingin, yang dipanaskan oleh roda gigi dan dikirim ke lorong panas, di mana udara panas dapat dihilangkan secara efektif dari ruangan. Pengaturan lorong juga dapat membantu memfasilitasi pengenalan pintu tambahan dan langkah-langkah keamanan di ujung setiap lorong untuk membatasi akses manusia.

Keamanan data center

Keamanan data center biasanya melibatkan tiga aspek berbeda yaitu keamanan akses, keamanan fasilitas, dan keamanan siber.

Akses keamanan. Setiap pembahasan fasilitas data center harus melibatkan pertimbangan keamanan fisik. Keamanan fisik adalah pengelolaan personel manusia dan perlindungan fasilitas fisik serta infrastruktur TI-nya. Ketika diterapkan dengan benar, keamanan memastikan bahwa hanya personel yang berwenang yang memiliki akses ke fasilitas dan perlengkapan, dan bahwa semua aktivitas manusia didokumentasikan. Keamanan dapat melibatkan serangkaian tindakan berikut:

  • akses badge ke dalam dan di sekitar fasilitas (termasuk area peralatan);
  • akses kunci ke rak dan server tertentu;
  • log untuk akses karyawan dan pengunjung/vendor;
  • pendamping untuk non-karyawan;
  • CCTV; Dan
  • petugas keamanan di tempat.

Keamanan fasilitas. Keamanan fisik juga mencakup integritas lingkungan data center, termasuk suhu, kelembapan, dan kondisi asap/kebakaran/banjir. Aspek perlindungan data center ini sering ditangani oleh BMS yang memantau dan melaporkan kondisi lingkungan atau darurat kepada pengelola gedung.

Keamanan cyber. Cybersecurity berfokus pada pengendalian akses ke data perusahaan dan aplikasi yang dihosting dalam infrastruktur TI data center. Cybersecurity dimaksudkan untuk memastikan bahwa hanya pengguna yang diautentikasi dengan benar yang dapat mengakses data atau menggunakan aplikasi, dan setiap pelanggaran dilaporkan dan segera ditangani. Misalnya, keamanan fisik mencegah manusia menyentuh disk di pusat data, sementara keamanan siber mencegah manusia yang sama mengakses data di disk dari jarak ratusan mil di seluruh jaringan. Cybersecurity menggunakan campuran antimalware, manajemen konfigurasi, deteksi/pencegahan intrusi, pencatatan aktivitas, dan alat lain untuk mengawasi aktivitas jaringan dan mengidentifikasi potensi ancaman.

Data center power and performance demands

Power is a perpetual challenge for any enterprise-class data center. A large facility can consume about 100 megawatts -- enough to power around 80,000 homes -- and power poses the single biggest Opex for an enterprise-class data center. Therefore, data center operators place the following demands on utility power:

  • Capacity. There must be adequate power to run the data center.
  • Cost. Power must be as inexpensive as possible.
  • Quality. Power must be electrically clean (i.e., free of undesirable electrical noise, surges and spikes).
  • Reliability. Power must be free of brownouts, blackouts or other disruptions.

These issues are increasingly addressed with locally generated and increasingly renewable options, including wind, solar and on-site generation.

But for a business to understand power issues for any data center site, it's important that data center designers and IT leaders calculate the power demands of the facility and its IT infrastructure. It's this benchmark that enables a business to understand approximate power costs and discuss capacity with regional utilities.

There is no single means of estimating power requirements. For the facility, power is a straightforward estimate of lighting and HVAC demands. IT infrastructure power demands can be more convoluted because server power requirements fluctuate with workload -- i.e., how much work the applications are doing -- and the configuration of each server, including the selection of CPU, installed memory and other expansion devices, such as GPUs.

Traditional power estimates include rack-based and nameplate-based approaches.

The rack-based approach generally assigns a standardized power-per-rack estimate. For example, an IT leader might assign an estimate of 7 kW to 10 kW per rack. If the data center plans to deploy 50 racks, the power estimate is a simple multiple. A similar approach is a general estimate of data center in watts per square foot (W/ft2). However, since this approach pays little attention to the equipment installed in each rack, it is often the most inaccurate means of power estimation.

The nameplate-based approach enables IT leaders to add up the power requirement listed on the nameplate of each server or other IT device. This is a more granular approach and can typically yield better estimates. Still, the power demand listed on each device nameplate can be notoriously inaccurate and doesn't consider the actual work the device is doing.

A more recent approach is to use actual power measurements per server, taken with IT power-handling devices, such as intelligent power distribution units (PDUs), located within each rack. Actual measurements can yield the most accurate estimates and give data center operators a better sense of how power demands and costs can fluctuate with workload demands.

Finally, utility power will inevitably experience occasional disruptions in generation and distribution, so data centers must include one or more options for redundant or backup power. There can be several layers of secondary power put in place, depending on which issues the business intends to guard against.

At the facility level, a data center can incorporate diesel or natural gas-powered backup generators capable of running the entire facility over the long term. Backup power can be supplemented by local renewable energy sources, such as solar or wind farms. At the IT infrastructure level, racks can incorporate UPS options, which provide short-term battery backups to enable an orderly system shutdown when power disruptions become unavoidable.

UPS under normal power diagram A full-time double conversion UPS design under normal utility power. UPS during power failure diagram A dual conversion UPS design when utility power fails.

Data center cooling systems

The power delivered to a data center is translated into work performed by the IT infrastructure, as well as an undesirable byproduct: heat. This heat must be removed from servers and systems, and then exhausted from the data center. Consequently, cooling systems are a critical concern for data center designers and operators.

There are two primary cooling issues. The first issue is the amount of cooling required, which ultimately defines the size or capacity of the data center's HVAC subsystems. However, designers must make the translation from the data center's power demand in watts (W) to cooling capacity gauged in tons (t) -- i.e., the amount of heat energy required to melt one ton of ice at 32 degrees Fahrenheit in one hour. The typical calculation first requires the conversion of watts into British thermal units (BTU) per hour, which can then be converted into tons:

W x 3.41 = BTU/hour
BTU/hour / 12,000 = t

The key is understanding the data center's power demands in watts and planned scalability, so it's important to right-size the building's cooling subsystem. If the cooling system is too small, the data center can't hold or scale the expected amount of IT infrastructure. If the cooling system is too large, it poses a costly and inefficient utility for the business.

The second cooling issue for data centers is efficient use and handling of cooled and heated air. For an ordinary human space, just introducing cooled air from one vent and then exhausting warmed air from another vent elsewhere in the room causes mixing and temperature averaging that yields adequate human comfort. But this common home and office approach doesn't work well in data centers, where racks of equipment create extreme heat in concentrated spaces. Racks of extremely hot gear demand careful application of cooled air, and then deliberate containment and removal of heated exhaust. Data center designers must take care to avoid the mixing of hot and cold air that keeps human air-conditioned spaces so comfortable.

Designers routinely address server room air handling through the use of containment schemes, such as hot aisle/cold aisle layouts. Consider two rows of equipment racks, where the rears face each other (see second diagram below). Cold air from the HVAC system is introduced into the aisles in front of each row of racks, while the heated air is collected and exhausted from the common hot aisle. Additional physical barriers are added to prevent the heated air from mixing with the cooled air. Such containment schemes offer a very efficient use of HVAC capacity.

Data center without hot/cold aisles diagram In data centers that don't use a hot/cold aisle design, the cooling units aren't always able to efficiently cool equipment. Data center with hot/cold aisles diagram In data centers designed around hot/cold aisles, the cooling units are able to more efficiently cool equipment. Other approaches to cooling include end of row and top of rack air-conditioning systems, which introduce cooled air into portions of a row of racks and exhaust heated air into hot aisles.

Some data centers even embrace emerging liquid cooling technologies that immerse IT gear in baths of chilled, electrically neutral liquids, such as mineral oils. The liquid chiller is small and power-efficient, and liquids can offer many times more heat transfer efficiency than air cooling. However, liquid cooling faces other challenges, including leaks/flooding, part corrosion or susceptibility to liquid intrusion, liquid filtering and cleanliness, and human safety.

Air cooling systems diagram This diagram shows the basic concepts of room-, row- and rack-based cooling architectures. The blue arrows indicate the relation of the primary cooling supply paths to the room.

Data center efficiency and sustainability

Today's concerns about the environmental impact of CO2 emissions from power generation have prompted many organizations to place new emphasis on the efficiency and sustainability of the data center.

Efficiency is fundamentally a measure of work done versus the amount of energy used to do that work. If all that input energy is successfully converted into useful work, the efficiency is 100%. If none of that input energy results in successful work, the efficiency is 0%. Businesses seek to improve efficiency toward 100% so that every dollar spent in energy is driving useful data center work.

Measures such as power usage effectiveness (PUE) are available to help organizations gauge efficiency. PUE is calculated as the power entering the data center divided by the power used in the IT infrastructure. This yields a simple ratio that approaches 1.0 as efficiency approaches 100%, and the corresponding percentage is expressed as data center infrastructure efficiency. Businesses can improve the PUE ratio by reducing the amount of energy in non-IT uses, such as reducing lighting and cooling in non-IT spaces and implementing other energy-efficient building designs.

PUE flowchart Power usage effectiveness is a metric used to assess the efficiency of a data center. Sustainability is another concern. Power generation creates pollution that is believed to drive climate change and reduce the health of the planet. Creating a sustainable or green data center means to strive for net zero carbon emissions for the power that drives data centers. Net zero means that energy is obtained from renewable sources that add zero CO2 to the atmosphere.


In some cases, the business can choose to approach net zero by using power from nonpolluting sources, such as solar or wind farms. In other cases, power can be purchased from power providers capable of capturing or recovering an equivalent amount of CO2 emitted in energy production, yielding net zero emissions. To achieve net zero, businesses must embrace energy conservation, energy efficiency -- such as PUE initiatives -- and renewable nonpolluting energy sources.

Green data storage chart Reduce data storage energy consumption to run a greener data center.

Data center design best practice

Tidak ada cara tunggal untuk merancang sebuah data center, dan ada banyak sekali desain yang memenuhi kebutuhan unik setiap bisnis. Tetapi strategi berikut dapat menghasilkan desain data center dengan efisiensi dan keberlanjutan yang unggul:

  • Measure power efficiency. Operator pusat data tidak dapat mengelola apa yang tidak mereka ukur, jadi gunakan metrik seperti PUE untuk mengawasi efisiensi data center. PUE harus menjadi pengukuran berkelanjutan yang dilakukan pada interval yang sering, sepanjang tahun, karena musim dan cuaca dapat memengaruhi penggunaan daya.
  • Revisit airflow. Pendinginan sangat penting untuk pengoperasian infrastruktur TI yang aman, tetapi aliran udara harus dikelola dan dioptimalkan. Ini dapat mencakup pembatasan pencampuran udara panas/dingin, menggunakan skema penahanan lorong panas/dingin dan bahkan menggunakan pelat blanking untuk menutup bukaan rak yang tidak terpakai, yang mencegah udara dingin mengalir ke tempat yang tidak mendinginkan peralatan apa pun.
  • Raise the temperature. Semakin dingin ruang server, semakin haus daya dan mahal. Daripada menjaga ruang server lebih dingin, evaluasi efek dari menaikkan suhu sebenarnya. Misalnya, daripada menjalankan lorong dingin pada suhu 68 hingga 72 derajat Fahrenheit, pertimbangkan menjalankan lorong dingin pada suhu 78 hingga 80 derajat Fahrenheit. Sebagian besar perlengkapan IT dapat mentolerir suhu tinggi dengan cara ini.
  • Try alternative cooling. Sistem HVAC mungkin standar untuk pusat data, tetapi pertimbangkan cara untuk mengurangi atau menghilangkan ketergantungan pada HVAC konvensional. Misalnya, data center di iklim yang lebih dingin dapat mengurangi penggunaan HVAC dan memasukkan udara luar yang lebih sejuk -- disebut pendinginan gratis -- ke dalam fasilitas. Demikian pula, HVAC dapat dilengkapi atau diganti dengan pendingin berpendingin air - yaitu, economizers - atau teknologi pertukaran panas lainnya yang menggunakan energi jauh lebih sedikit.
  • Improve power distribution. Efisiensi daya data center sering kali hilang karena inefisiensi dalam penanganan daya dan perangkat distribusi, seperti transformator peralatan, PDU, dan perlengkapan UPS. Gunakan roda gigi distribusi daya berefisiensi tinggi dan minimalkan roda gigi -- keduanya menghasilkan langkah yang lebih sedikit dan peluang kehilangan.

Tantangan desain data center

Meskipun tidak ada formula tunggal yang seragam untuk desain dan konstruksi data center, ada banyak tantangan abadi yang dihadapi oleh perancang dan operator data center. Di bawah ini adalah beberapa pertimbangan dan tantangan yang luas:

  • Scalability. Data center adalah instalasi jangka panjang yang dapat tetap beroperasi selama beberapa dekade, tetapi data center yang beroperasi saat ini mungkin berbeda secara signifikan dari data center yang beroperasi satu atau dua dekade dari sekarang. Desainer harus mempertimbangkan cara menangani beban kerja dan layanan saat ini, sambil juga mempertimbangkan bagaimana sumber daya tersebut harus diskalakan dengan baik ke masa depan. Tantangannya adalah menyediakan ruang untuk pertumbuhan ruang, daya, dan pendinginan sambil mengurangi biaya kapasitas tersebut hingga dibutuhkan.
  • Flexibility. Pusat data sedikit mirip dengan lantai produksi yang berat: Peralatan sudah terpasang tetapi hampir tidak mungkin untuk dipindahkan dan diubah seiring berkembangnya permintaan. Ketidakmampuan untuk memindahkan gigi dan menggeser lorong dapat mencegah bisnis beradaptasi dan berubah untuk memenuhi permintaan bisnis baru. Tantangannya adalah memenuhi kebutuhan akan perubahan tanpa downtime atau desain ulang yang mahal dan memakan waktu.
  • Resilience. Sebuah bisnis bergantung pada data center-nya. Jika data center tidak berfungsi, bisnis tidak berfungsi. Gangguan listrik, gangguan jaringan, bencana lingkungan dan bahkan peretasan dan tindakan jahat lainnya dapat melumpuhkan data center. Desainer menghadapi tantangan untuk memahami ancaman yang paling umum dan merancang ketahanan yang tepat untuk menghadapi ancaman tersebut.
  • Change. Teknologi komputasi baru dan persyaratan baru selalu dikembangkan dan diperkenalkan. Perancang data center harus mempertimbangkan cara mengadaptasi dan menggabungkan perubahan yang sering tidak terduga tanpa perlu mendesain ulang infrastruktur TI secara mendasar untuk mengakomodasi setiap perubahan.

Data center infrastructure management software and tool

Data center adalah organisme kompleks yang memerlukan pemantauan dan manajemen berkelanjutan baik di tingkat fasilitas maupun infrastruktur TI. Operator data center biasanya menggunakan alat DCIM untuk memberikan perspektif ke dalam pengoperasian fasilitas dan infrastruktur. Serangkaian tugas manajemen umum yang diperlukan untuk mengoperasikan data center mencakup hal-hal berikut:

  • Pengamatan dan pengawasan. Tugas observasi meliputi pemantauan daya, suhu dan kelembaban di dalam fasilitas. Pengamatan dalam infrastruktur dapat mencakup kapasitas yang tersedia, artinya sistem mana yang digunakan dan mana yang gratis; kesehatan aplikasi untuk memantau operasi yang benar dari beban kerja utama perusahaan; dan waktu aktif atau ketersediaan secara keseluruhan. Tugas observasi biasanya dikaitkan dengan sistem peringatan dan tiket untuk memprioritaskan dan memulihkan masalah saat terdeteksi.
  • Persiapan dan perbaikan. Manajemen data center juga melibatkan tugas persiapan, seperti pemulihan bencana dan proses pencadangan, serta kemampuan migrasi beban kerja untuk memungkinkan tugas layanan sistem tepat waktu. Tugas perbaikan meliputi servis rutin, bersama dengan peningkatan sistem berkala dan pemecahan masalah dan perbaikan sistem ad hoc.
  • Kapasitas dan kemampuan. Manajemen data center juga tentang perencanaan untuk masa depan. Alat manajemen dapat mengawasi kapasitas saat ini -- yaitu, sumber daya yang digunakan versus sumber daya gratis -- dan membantu operator data center melacak pemanfaatan untuk merencanakan peningkatan kapasitas. Mereka juga membantu mendukung peningkatan reguler pada kemampuan pusat data, seperti pemutakhiran sistem, penyegaran teknologi, dan pengenalan teknologi pusat data baru.

Manajemen adalah elemen penting dalam jaminan layanan bisnis dan service level agreements (SLA). Banyak data center terikat oleh beberapa bentuk SLA -- baik ke departemen atau divisi internal atau ke mitra bisnis dan pelanggan eksternal. Pemantauan dan pengelolaan dengan DCIM dan alat lainnya sangat penting untuk menjamin kepatuhan terhadap SLA atau mengidentifikasi pelanggaran SLA yang dapat segera diisolasi dan diperbaiki. Selain itu, pemantauan dan manajemen yang komprehensif membantu memastikan kelangsungan bisnis dan pemulihan bencana, yang dapat menjadi penting untuk kewajiban kepatuhan terhadap peraturan saat ini.